CMC · Rolling doors and grilles

CMC UL labelled fire door

Fire doors · Commercial

Priced after a free measure

Special order, about 5 to 8 weeks to install.

  • Oversized or custom sizes are built to order and can add 1 to 2 weeks.
  • Powder coated or custom finishes can add about 3 to 5 weeks.

Typical estimate from order to install. We confirm your date when you order.

  • Product, installation and testing included
  • Licensed and insured in Florida
  • We call within one working day to book

A labelled rolling fire door for an opening in a fire rated wall. It stays open in daily use and closes on its own in a fire, when a fusible link melts or a listed release device takes a signal from the fire alarm or a smoke or heat detector. The curtain, hood, guides and closing hardware are one listed assembly, and NFPA 80 requires a drop test when it is installed and an inspection and drop test every year after.

Specifications

  • Listed and labelled assembly
  • Rating matched to the wall
  • Closes automatically

See the whole range →

Design your door: UL labelled fire door

The door is drawn to scale at the size you choose below, from the specification it is built to: the slat profile and gauge, the finish, the guides, the bottom bar and the hood. Screen colour is approximate; we bring a sample to the visit. Your picks travel with your quote.

Every option in this line
Slat
Flat slat, Insulated flat slat
Gauge
20, 18
Finishes
Galvanised, Primed white, Primed grey. Powder coat and other colours are quoted per order
Mounting
Face of wall or between jambs
Hood
Always hooded

Get your price

Choose your opening size and send your request with anything you picked above. Your written quote follows.

Common sizes (width x height, feet)

Opening width
Opening height

Where is the job?

Up to 4 photos from your phone. They help us bring the right parts.

We never share your info. Your privacy is protected. Prefer to talk? Call (786) 315-9238.

What it comes in

LabelFire rating label from the listing agency on the door, matched to the rating of the wall it closes
RatingsCommonly 3/4, 1, 1 1/2 or 3 hour, set by the wall and confirmed before ordering
ClosingCloses automatically by fusible link, or by a listed release device wired to the fire alarm or to smoke or heat detectors, at a controlled closing speed
ConstructionSteel curtain, hood and guides built and labelled as one listed assembly. A hood or guide from another door voids the label.
OperationChain hoist, or a motor operator listed for fire doors with a fail safe release, so the door still closes when the alarm sounds or the power fails
Gauges20 and 18 gauge steel, galvanised or primed. Insulated curtains and other finishes are quoted.
TestingDrop tested at installation, then inspected and drop tested every year under NFPA 80, with a written record for the fire inspector

Price: Quoted in writing within 24 hours of your opening size and wall rating, including the closing and release hardware and the acceptance drop test.

What happens next

1. Send the request

Send the request with your address. We reply with a written price.

2. We call you

Within one working day we confirm the address, the door and a time that suits you.

3. Installed and tested

Our technician installs it, tests it at your door and shows you how it works before leaving.